Light curtains
TLVT 
 

Prevention of bodily injuries of fingers, hands, and limbs, e.g. when working at:

  • wood working machines
  • packaging machines
  • textile machines
  • storing and materials-handling technology
  • insertion machines
  • revolving machines
  • palletizers

back to Feissler Safety Products

 

The safety light curtains TLVT are electrosensitive protective devices (EPSE) and are characterized by compliance with safety category 2, IEC 61496 parts 1 + 2 i.e. EN 61496 parts 1 + 2.


  • integrated control-unit with contactor control and restart activatable by DIP switches activatable
  • contactor/valves directly connectablly, switching capacity 0,5A/24V
  • smallest safety distances by short response times 6 ms to 25 ms, depending of the protection high
  • smallest obstacle recognition of 14mm up to 7m range
  • hand protection up to detection range of 24 m, recognition of smallest obstacles(30 mm)
  • protection heights of 100mm to 1900mm
  • microprocessor monitoring of the safety functions
  • self-monitoring semiconductor outputs with line interruption monitoring, short-circuit- and side current passages check.
  • built in selfdiagnostic with error display
  • minimum safety distance due to short response times, between 5 ms and 25 ms, depending on constructional lenght
  • protective system IP65
 
Function description 
 

The safety light curtains TLVT consist of the two components: transmitter and receiver. The distance between both components and the overall height result in those protection width and - height.

By the modular construction protection heights of 100mm to 1900mm are realizable. Special sizes are also available.

Transmitter and receivers operate synchronously, i.e. at the same point in time only a light beam and a reception item are active. The synchronisation is made by the first light beam and the first reception item. Between transmitter and receivers therefore no electrical connection is necessary.

The transmitter creates infrared light beams, which are switched on and off rapidly successively. The parallel light beams with a distance from 7,5mm are controlled by two a chip micro controllers. A resolution of 14mm is realised by the beam distance.

Synchronously to the light beams of the transmitter in the receiver all reception items are analysed by two a chip micro controllers. If an object is in the protection field, i.e. it is darkened at least one of the beams, the two outputs of the receiver interrupt the dangerous movement of the machine, or prevent a start. A renewed start of the machine is in the operating mode with restart only possible by pressing the start push-button during a free protection field.

Several LED at the receiver display thereby the respective operating condition. The system detects an internal or external error the machine is immediately switched off and the LED in the transmitter or in the receiver shows by flashing the error status.

 
Integrated connector plug in connector cover 
 

The TLVT construction series is supplied with PG threaded joints as standart. Various conventional connector plugs can also be obtained as optional accessories. The electric connection is implemented via terminal screws in the connector cover. The cover can be removed once the 4 screws have been loosened.

The transmitter is connected via a 3-core cable, the receiver is connected via a 5 to 7-coire cable(according to the mode of operation)

 
Operating mode 
 


DIP-position

Without contactor check


DIP-position

With contactor check

The operating mode with contactor control serves for monitoring the triggered follow-up contactors.
After each interruption of the optical path and before each release of the switching outputs the follow-up contaction are checked whether they dropped. If the contactors don´t dropped with in 300ms the light curtain output contacts go into lock status.




DIP-position

Without restart interlock


DIP-position

With restart interlock

IIf the operating mode with restart control is adjusted, a push-button must be connected for the start release of the working movement.
With a free protection field the yellow LED lights up. After actuating the start push-button the two outputs of the TLVT are activ.




DIP-position

Equivalent outputs


DIP-position

Antivalen outputs

During the operational mode equivalent outputs both PNP outputs and provide short-circuit- and side-current passages monitoring.

With free optical path both outputs are high(+24V). During the operational mode antivalent outputs, output No. 1 is high (+24V) and output No. 2 low (0V), with free optical path.

 
technical data 
 
  Transmitter TLVTS Receiver TLVTE
Supply voltage 24V DC SELV, +20% -10% 24V DC SELV, +/- 20%
Current consumption max. 250mA max. 250mA (without load)
Outputs - OSSD 1 and 2:
error-proof PNP outputs; max. 0,5A short-circuit and transverse conclusion monitoring
(in operating mode of antivalent outputs Output2 is not error-proof, max. 20mA)
Inputs - Inputs contactor control and start push-button: 0V to 24V DC + / - 20%, 10 mA
electrical link integrated plug connector with PG9 as strain relief;
alternatively usual market plug connectors
integrated plug connector with PG9 as strain relief;
alternatively usual market plug connectors
Lead 3-pol. max 1,5mm² 5 to 7-pol. (depending upon type of driving) max. 1,5mm²
 
Executions 
 
 
   
14 mm
14 mm
30 mm
30 mm
Protection box height (mm)
/ ray number
Construction length (mm)
Order data
reaction time (ms)
Order data
reaction time (ms)
100 / 13
196
TLVT 100 / 13
6
TLVT 100 / 7
5
200 / 26
296
TLVT 200 / 26
7
TLVT 200 / 14
6
300 / 39
396
TLVT 300 / 39
8
TLVT 300 / 21
6
400 / 52
496
TLVT 400 / 52
9
TLVT 400 / 28
7
500 / 65
596
TLVT 500 / 65
10
TLVT 500 / 35
7
600 / 78
696
TLVT 600 / 78
11
TLVT 600 / 42
8
700 / 91
796
TLVT 700 / 91
12
TLVT 700 / 49
9
800 / 104
896
TLVT 800 / 104
13
TLVT 800 / 56
9
900 / 117
996
TLVT 900 / 117
14
TLVT 900 / 63
10
1000 / 130
1096
TLVT 1000 / 130
15
TLVT 1000 / 70
10
1100 / 143
1196
TLVT 1100 / 143
17
TLVT 1100 / 77
11
1200 / 156
1296
TLVT 1200 / 156
18
TLVT 1200 / 84
12
1300 / 169
1396
TLVT 1300 / 169
19
TLVT 1300 / 91
12
1400 / 182
1496
TLVT 1400 / 182
20
TLVT 1400 / 98
13
1500 / 195
1596
TLVT 1500 / 195
21
TLVT 1500 / 105
13
1600 / 208
1696
TLVT 1600 / 208
22
TLVT 1600 / 112
14
1700 / 221
1796
TLVT 1700 / 221
23
TLVT 1700 / 119
15
1800 / 234
1896
TLVT 1800 / 234
24
TLVT 1800 / 126
15
1900 / 247
1996
TLVT 1900 / 247
25
TLVT 1900 / 133
16
 
Download 
Product
Documentation
Deutsch
Amerikan English
Muting
Description of the muting funkcion of the guard light barriers
-
TLVT
Appliance description
TLVT
Operating instructions
TLVT
Dimensional drawings of XLVT 100-1900 in stp,igs,dxf,dwg
 
 


Manufacturing Solutions, Inc. - Corporate Ofice
P.O. Box 427
Lawrenceburg, TN  38464
Office:  (931) 762-8773
Fax:  (931)766-0083

sales@mfg-sol.com

 
email to sales@mfg-sol.com