REES 04954-414, Cable/Rope Operated Switch    ree rees electrical controls logo

REES 04954-414,  Cable/Rope Operated Switch

List Price $881.30    Back to Store  / REES

Features/Applications

The following “slack cable” style switch has 2 NO and 2 NC make-before-break contacts on each end. This switch is particularly competent for use in Emergency Stop applications as well as for ordinary circuit control.

The housing is made from high quality die-cast aluminum and powder coated painted yellow. The independently operating red indicating flags rotate 90 degrees when tripped. Manually returning the flags to their normal position resets the switch.

  • Manual reset with “Positive Break” contacts
  • Gold plated contacts eliminate high resistance tarnishing
  • Bi-Directional with Dual Flags
  • Nema 4X (indoor), IP 66

Each captive terminal will accept (2) #14 AWG stranded wires. Each switch is supplied with a fibreflex gasket which provides an oil tight seal upon installation. For added protection against corrosive environments a neoprene gasket is available as an accessory item by ordering part number 02005-540.

There are two ¾ NPT conduit openings. The maximum cable recommended cable length is 200 feet per end with a maximum interval support of 10 feet.

The mechanical life of the switch is 150,000 operations.

This switch can be installed on various conveyor installations and provides a constant access for emergency or normal stopping.

The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments.

Contact blocks are UL Listed and CSA/DEMKO Certified, however, the assembled switch is not.

Electrical Ratings

“HEAVY DUTY – A600 / N150”

CE Compliant IEC/EN 60947-5-1

Environmental Temperature Range

Operating: +32oF to +131oF (0oC to +55oC)

Storage: -40oF to +185oF (-40oC to +85oC)

Note: Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

Normal Potential  Normal Current  Inrush Current 
110-120 acvolts 6.0 amp. 60.0 amp.
220-240 aca 3.0 amp. 30.0 amp.
440-480 aca 1.5 amp. 15.0 amp.
550-600 aca 1.2 amp. 12.0 amp.
115-125 dcb 2.2 amp. -----

 Power factor 0.35 or less

 Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

 

Specifications  

Trip Force per End

25 lb

Operating Force Between 10 ft. Supports

6 lb

Reset Type

Manual

Contact Arrangement

2 NO + 2 NC
(make-before-break)

Contact Arrangement Each End

(2) NO/NC
(make-before-break)

Type / Style

Flags

 

More Images

Dimensional Drawing

Temperature Effects on Cable

Typical Accessory Usage

 Warning - Danger(PDF, 77KB)

 Glossary of Common Terms(PDF, 234KB)

  Cable/Rope Operated Switches Product Line Review(PDF, 471KB)

 Rating Codes(PDF, 28KB)

Installation Instruction Sheet(PDF, 775KB)