REES 04944-240, Cable/Rope Operated Switch    ree rees electrical controls logo

REES 04944-240,  Cable/Rope Operated Switch

List Price $652.70    Back to Store  / REES

Features/Applications

The following “slack cable” style switch has 2 NO and 2 NC contacts.   This switch is particularly competent for use in Emergency Stop applications as well as for ordinary circuit control.

The housing is made from high quality die-cast aluminum and powder coated painted yellow.

  • Manual reset with “Positive Break” contacts
  • Gold plated contacts eliminate high resistance tarnishing
  • Nema 12/13, IP 65
  • May be mounted for right or left hand pull

Each captive terminal will accept (2) #14 AWG stranded wires. Each switch is supplied with a fibreflex gasket which provides an oil tight seal upon installation. For added protection against corrosive environments a neoprene gasket is available as an accessory item by ordering part number 02005-540.

There are two ¾” NPT conduit openings. The maximum cable recommended cable length is 200 feet with a maximum interval support of 10 feet.

The mechanical life of the switch is 150,000 operations.

This switch can be installed on various conveyor installations and provides a constant access for emergency or normal stopping.

The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments.

Electrical Ratings

“HEAVY DUTY – A600 / N300”

Listed under UL 508 – File # E 58589

Certified under CSA C22.2 – File # LR 3648

CE Compliant IEC/EN 60947-5-1

Third party certified under DEMKO Certificate # D-01474-M1

Environmental Temperature Range

Operating: +32oF to +131oF (0oC to +55oC)

Storage: -40oF to +185oF (-40oC to +85oC)

Note: Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

 

Normal Potential Normal Current Inrush Current
110-120 acvolts 6.0 amp. 60.0 amp.
220-240 aca 3.0 amp. 30.0 amp.
440-480 aca 1.5 amp. 15.0 amp.
550-600 aca 1.2 amp. 12.0 amp.
115-125 dcb 2.2 amp. -----
230-250 dcb 1.1 amp. -----

 Power factor 0.35 or less

 Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

 

Specifications  

Color

Yellow

Trip Force

15 lb

Operating Force Between 10 ft. Supports

3.8 lb

Reset Type

Manual

Contact Arrangement

2 NO +  2 NC

Old Catalog Number

2669

 

More Images

Dimensional Drawing

Temperature Effects on Cable

Typical Accessory Usage

 Warning - Danger(PDF, 77KB)

 Glossary of Common Terms(PDF, 234KB)

  Cable/Rope Operated Switches Product Line Review(PDF, 471KB)

 Rating Codes(PDF, 28KB)