REES 03275-000, Cable/Rope Operated Switch    ree rees electrical controls logo

REES 03275-000,  Cable/Rope Operated Switch

Back to Store  / REES

Features/Applications

 This switch is a slack cable style with 1 NO and 1 NC momentary “Slow-Make – Slow Break” contacts. This switch also has “Positive Break” contacts and may be used as an emergency stop switch.

This low activating force switch is basically a pushbutton device operated through a nickel plated operating lever attached to the cover. Care must be taken when choosing and installing the operating rope because the low operating force can be easily overcome and the switch will not trip or reset properly.

This switch requires a suitable enclosure which must be purchased separately. One enclosure suggestion is Rees number 02765-000. A sealing gasket and four mounting screws are supplied with each switch.

Each captive terminal will accept (2) #14 AWG stranded wires.

  • Low operating force
  • Gold plated contacts eliminate high resistance tarnishing
  • Positive Break contacts
  • Nema 12/13, IP 65                                                                      

The maximum recommended rope length is 33 feet with a maximum interval support of 10 feet when horizontal.

The mechanical life of the switch is in excess of 1,000,000 operations.

Electrical Ratings

“HEAVY DUTY – A600 / N300”
Listed under UL 508 – File # E 58589
Certified under CSA C22.2 – File # LR 3648
CE Compliant IEC/EN 60947-5-1
Third party certified under DEMKO Certificate # D-01496-M1

 Environmental Temperature Range

Operating: +32oF to +131oF (0oC to +55oC)
Storage: -40oF to +185oF (-40oC to +85oC)

Note: Operating temperatures at 0oC are based on the absence of freezing moisture and liquids.

Normal Potential Normal Current Inrush Current
110-120 acvolts 6.0 amp. 60.0 amp.
220-240 aca 3.0 amp. 30.0 amp.
440-480 aca 1.5 amp. 15.0 amp.
550-600 aca 1.2 amp. 12.0 amp.
115-125 dcb 2.2 amp. -----
230-250 dcb 1.1 amp. -----

 Power factor 0.35 or less

 Inductive loads as specified in Section 125 of Industrial

   Control Devices, Controllers and Assemblies, ANSI /

   NEMA ICS 2-1988

 

Specifications  

Trip Force

6 lb

Operating Force Between 10 ft. Supports

0.7 lb

Operating Type

Momentary Slow Make/Slow Break

Contact Arrangement

#9  NO + NC

Old Catalog Number

3275

 

More Images

Dimensional Drawing

Temperature Effects on Cable

Typical Accessory Usage

Contact Arrangement

Back View

 Warning - Danger(PDF, 77KB)

 Glossary of Common Terms(PDF, 234KB)

  Cable/Rope Operated Switches Product Line Review(PDF, 471KB)

 Rating Codes(PDF, 28KB)

Installation Instruction Sheet(PDF, 85KB)